Error Code P065C: What It Means & What To Do?
OBD Code P065C - Generator Mechanical Performance
The
P065C trouble code can be identified as Generator Mechanical Performance. The
generator is controlled by the engine control module by using a generator turn
ON signal circuit. A high side driver within the ECM allows the ECM to turn the
generator ON and OFF. Now when the generator operation is desired, the ECM
sends a 5-volt signal to the voltage regulator via the generator turn on signal
circuit. This would cause the voltage regulator to start controlling the
generator field circuit.
Learn More About OBD Error Code P065C
Willing
to learn more about this fault code? Then you have arrived at the right place.
There are some cases where the alternator is also known as generator but more
frequently this type of code is used in a hybrid or electric vehicle which
generates electrical power from a generator.
What causes this problem with
the Generator Mechanical Performance?
- Defaults
in the controller or PCM
- The
fuse, relay, or fusible link might have some flaws
- There
can be some faults in the generator
- The
harness of the generator might be opened or shorted
- Bad
electrical connection in the generator circuit
- Programming
error in the powertrain control module
Replace/Repair These Parts To Fix OBD Code P065C
- Electronic Control
Unit - A faulty Electronic
Control Unit can be troublesome. You can always rely on us as we have best
auto parts for our customers.
- Powertrain Control
Module - If everything is
alright with Electronic Control Unit, then there is surely some defect in
Powertrain Control Module. Get it replaced before the situation gets worse.
- Engine Control
Module - P065C code can display
due to some issues in the Engine Control Module. So, it is very important to
replace the Engine Control Module with us at equitable prices.
- Alternator - Do you remember when was the
last time you got your car Alternator checked up? A
dirty Alternator can cause a lot of issues like displaying P065C
code.
Symptoms Of OBD Error Code P065C
There could be countless symptoms which that
would accompany with this fault code. Willing to know some common symptoms of
OBD Trouble Code P065C? Your wish is our demand. Have a look at them below:
Common Symptoms
- Issue of delay or no start in the car engine
- Appearance of the engine light
- Electrical accessories might not be functional
- There can be some engine drivability problems
How To Correct P065C Generator Mechanical Performance
Looking out for some ways with the help of
which you can correct this fault code? Then you have arrived at the correct
place. We are here to help you out, so you must check out the steps mentioned
below as follows:
- If you find out that the harness of the
generator is opened or shorted, then it should be repaired properly
- Correct the issue of bad electrical connection
in the generator circuit
- Make sure to repair the PCM programming error
- The defective generator should be repaired or
replaced
- You can always restore the faulty fuse, relay,
or fusible link
- Repair or replace the PCM
Don’t get tensed if you are still facing any of these issues as we care for our customers and that’s why we offer a good range of Multimeter, Code Scanner, Obd2 Scanner, Voltmeter, Obd2 Bluetooth, Ohmmeter, Fusible Link, Digital Multimeter, Diagnostic Tools, Digital Voltmeter, Analog Multimeter, Fusible Link Wire, Gm Alternator Wiring and a lot more. We are sure that now all your issues would be resolved.
Easy Diagnosis Of Engine Error OBD Code P065C
It is essential to diagnose this fault code.
Here are some steps which a mechanic should follow for diagnosing the problem
that triggered a P065C code to be stored:
- Keep one thing in mind that the car battery is
completely charged and at the generator should be functioning properly before
you start diagnosing the P065C error code
- Make sure to consult your vehicle information
source for technical service bulletins (TSB) that replicate the code stored,
vehicle (year, make, model, and engine), and symptoms exhibited
- If you find the appropriate TSB, it may yield
helpful diagnostic information. A diagnostic scanner and a digital
volt/ohmmeter will be necessary to accurately diagnose a code P065C. A reliable
source of vehicle information will also be needed
- You should start by connecting the scanner to
the vehicle diagnostic port and retrieving all stored codes and freeze frame
data
- You will want to write this information down,
just in case the code proves to be an intermittent one. Now once all the
pertinent information has been recorded, then you should clear the codes and
test drive the vehicle until the code is reset or the PCM enters readiness mode
- If the PCM enters readiness mode, the code is
intermittent and will be even more difficult to diagnose. The condition, which
caused the P065C to be stored, may need to worsen before an accurate diagnosis
can be reached
- On the other hand, if the code fails to reset
and there are no drivability symptoms exhibited, the vehicle can be operated
normally
- If the P065C is immediately reset, proceed
with a visual inspection of system related wiring and connectors. Harnesses
that have been broken of unplugged should be repaired or replaced as required
- Once you have the correct information, test
all system fuses and relays to make sure the generator is being supplied
voltage
- If generator supply voltage is not present,
trace the appropriate circuit back to the fuse or relay from which it
originates. Repair or replace defective fuses, relays, or fusible links as
required
- In some cases, generator supply voltage is
routed through the PCM. You may use wiring diagrams and other vehicle specific
information to help diagnose generator voltage supply malfunctions
- If generator supply voltage is present, use
your DVOM to test generator output performance at the appropriate pin of the
generator connector
- If the appropriate level of generator output
voltage is not discovered, suspect that the generator is defective
Should the level of voltage at the PCM connector differ (by more than 10-percent) between what is detected at the generator connector, suspect a shorted or open circuit between the two. If you want to avoid the misdiagnosis, then you must test the generator fuses with the circuit loaded